Configuring WAN Line Services
A-12
117345-B Rev. 00
Parameter: Mini Dacs
Path: E1 Connector > Edit Line > Edit E1 Parameters
Default: Idle
Options: Idle
|
Data
|
Voice
|
Circuit 1
|
Circuit 2
Function: Assigns a specific function to each E1 channel.
Instructions: Select Idle to make the channel idle.
Select Data to assign the channel to voice pass-through (E1 connector to E1
connector).
Select Circuit 1 to assign the channel to the first E1 connector.
Select Circuit 2 to assign the channel to the second E1 connector.
MIB Object ID: 1.3.6.1.4.1.18.3.4.11.1.9
Parameter: Line Type
Path: E1 Connector > Edit Line > Edit E1 Parameters
Default: E1
Options: E1
|
E1CRC4
Function: Enables or disables a 4-byte CRC on received frames.
Instructions: Select E1CRC4 if the E1 equipment expects a 4-byte CRC trailer at the end of
each frame.
MIB Object ID: 1.3.6.1.4.1.18.3.4.11.1.18