Configuring WAN Line Services
2-32
117345-B Rev. 00
Configuring Asynchronous Services
The implementation of asynchronous services differs among Bay Networks
routers. On Octal Sync link modules, all synchronous net modules, and BayStack
router COM ports, you can configure asynchronous communication from the Edit
SYNC Parameters window by:
Setting the WAN Serial Interface Type
Setting the Asynchronous Baud Rate
For all other synchronous link modules, these parameters are not available. See
Chapter 3
for information about additional asynchronous services on BayStack
AN and ANH routers.
Setting the WAN Serial Interface Type
The serial interface is set for synchronous operation by default. Set this parameter
to Async to select asynchronous communication; set it to Pasync for polled
asynchronous communication.
Using Site Manager
See the WAN Serial Interface Type parameter on page A-72 for information.
Setting the Asynchronous Baud Rate
With the WAN Serial Interface Type parameter set to Async, you can set the
transmission speed (in bits per second) between the router and the modem. You
control the baud rate for asynchronous PPP using the Async Baud Rate parameter.
Set this parameter to a value that is greater than or equal to the speed at which the
modem connects, but that is independent of that speed. For example, you set a
V.34 modem to its maximum modular connection speed of 28800 Kb/s or higher.
However, you could set the baud rate for a V.42bis or MNP 5 data compression
modem with a high (4 to 1) compression ratio to 115200 baud.
By default, the asynchronous baud rate is 9600. Select a baud rate from 1200 to
115200 baud.