Configuring WAN Line Services
8-4
117345-B Rev. 00
How you access this window is based on whether or not you have already
configured the port.
• For an unconfigured FT1 link module
The first time you configure a port, the Edit FT1 Clock Parameters window
opens automatically. When you set these clock parameters, you define the
timing sources for the selected port only.
• For a configured FT1 link module
Display the FT1 Port Parameters window (FT1 Connector > Edit Logical
Lines > Port Details > FT1 Port Parameters).
To set the clock parameters:
For the primary or secondary clock, you can set the value to Internal to use the
clock chip on the link module. Otherwise, you can set the value to Port 1 Ext Loop
so that the clock uses the signal coming in from port 1.
Site Manager Procedure
You do this System responds
1. In the window containing the clock
parameters, select a primary clock source
option.
2. Set the
Primary Clock
parameter, using
Help
or see the parameter description on
page A-49
.
3. Select the secondary (backup) clock
source option.
4. Set the
Secondary Clock
parameter,
using
Help
or see the parameter
description on page A-49
.
5. Click on
OK
. The FT1 Port Parameters window
(Figure 8-3)
opens.