Configuring FDDI Services
308623-14.00 Rev 00
3-21
Specifying the Maximum TTRT
The maximum TTRT value must be:
Greater than or equal to 10 ms
Greater than or equal to the value of the requested TTRT
Less than or equal to 1336.9344 ms
See Figure 3-2
on page 3-19 for the range of values for the maximum TTRT, in
relation to the other TTRT values.
To set the maximum TTRT value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose a
FDDI
Connector.
The Edit Connector window opens.
2. Choose
Edit Line
. The Edit FDDI Parameters window
opens.
3. Choose
Expert
. The FDDI Advanced Attributes window
opens.
4. Choose
Path Attributes
. The FDDI Path Attributes window opens.
5. Set the
T_Max Lower Bound (ms)
parameter. Click on
Help
or see the
parameter description on page A-23.
6. Click on
OK
. You return to the FDDI Advanced
Attributes window.
7. Click on
Done
. You return to the Edit Connector window.
8. Click on
Done
. You return to the Configuration Manager
window.