Configuring FDDI Services
308623-14.00 Rev 00
3-11
For example, to set the SMT connection policy, enter the following command
sequence:
box# fddi slot 11 connector 1
fddi/11/1# reject-policy a-a
Using Site Manager
To set the SMT connection policy, complete the following tasks:
Specifying the Neighbor Notification Interval
Neighbor information frames (NIFs) identify the upstream and downstream
neighbors of each node. A Nortel Networks station issues a response to the sender
of a NIF frame and generates NIF requests as part of the neighbor notification
process.
You can set the interval between successful iterations of the Neighbor Notification
Protocol on an interface to a value from 2 to 30 seconds. By default, the interval is
22 seconds. This interval:
Determines the MAC addresses of the upstream and downstream neighbors
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose a
FDDI
Connector
.
The Edit Connector window opens.
2. Choose
Edit Line
. The Edit FDDI Parameters window
opens.
3. Choose
Expert
. The FDDI Advanced Attributes window
opens.
4. Choose
SMT Attributes
. The FDDI SMT Attributes window opens.
5. Set the
Connection Policy
parameter.
Click on
Help
or see the parameter
description on page A-20.
6. Click on
OK
. You return to the FDDI Advanced
Attributes window.
7. Click on
Done
. You return to the Edit Connector window.
8. Click on
Done
. You return to the Configuration Manager
window.