Parameter: TDisc
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 4
Options: 1 to 180
Function: Specifies the SAAL Data Link Disconnect timer value (in seconds). This
internal timer alerts upper layers that the link is down. The timer begins if the
entire link goes down for any reason.
When the link goes down, the SAAL sends a DISCONNECT REQUEST
message to the upper-layer application manager. The SAAL sends a disconnect
request every time the SAAL Data Link Disconnect timer expires and continues
to send this message until the link becomes operational.
Instructions: Accept the default, 4, or enter a value from 1 to 180.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.33
Parameter: T398
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 4
Options: 1 to 24
Function: Specifies the Drop Party Sent timer value (in seconds). This timer applies to
multipoint connections only and begins when the circuit sends a DROP PARTY
message to a party (the receiver of the message) on the network.
The Drop Party Sent timer stops when the circuit receives a DROP PARTY
ACKNOWLEDGE message (indicating that the end point used for the party has
been released) or a RELEASE message (indicating that the end point used for
the party has been released and there are no remaining parties).
Instructions: Accept the default, 4, or enter a value from 1 to 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.34