Avaya Configuring ATM and MPLS Services Manual de usuario Pagina 169

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 529
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 168
Customizing Signaling
117374-C Rev 00
5-21
Using Site Manager
To change a signaling timer value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
ATM
. The Edit ATM Connector window opens.
3. Click on
ATM Signaling
. The ATM Signaling Parameters window
opens.
4. Set one or more of the following timers:
•T303
•T308
•T309
•T310
•T313
•T316
T316c
•T322
•TDisc
•T398
•T399
Click on
Help
or see the parameter
descriptions beginning on page A-45.
5. Click on
Done
. You return to the Edit ATM Connector
window.
6. Click on
Done
. You return to the Select Connection Type
window.
7. Click on
Done
. You return to the Configuration Manager
window.