Customizing an ATM Interface
117374-C Rev 00
4-11
Using Site Manager
To change the clocking signal source for the ATM line, complete the following
tasks:
Specifying DS-3 Line Buildout
On modules that use a DS-3 interface, you can specify how the router conditions
signals to migrate attenuation. Specify a short line (the default) for a line less than
225 feet (ft) long. Specify a long line for a line length of 225 ft or more.
Using the BCC
To change the DS-3 line buildout, navigate to the atm prompt (for example,
box;
atm/11/1
) and enter:
ds3-line-build-out
<length>
length
is either short (default) or long.
For example, the following command changes the DS-3 line buildout to long:
atm/11/1#
ds3-line-build-out long
atm/11/1#
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
Line Attributes
. The ATM/ARE Line Driver Attributes
window opens.
3. Set the
Clocking Signal Source
parameter. Click on
Help
or see the
parameter description on page A-9.
4. Click on
OK
. You return to the Select Connection Type
window.
5. Click on
Done
. You return to the Configuration Manager
window.
Comentarios a estos manuales