Setting the Maximum Data Frame Size
The maximum data frame size is the largest frame that the LE client can:
Send on the multicast send VCC.
Receive on the multicast forward VCC.
Send and receive on data direct VCCs.
When you accept the default, unspecified, the LEC obtains the maximum data
frame size when it joins an ELAN. However, you can limit the maximum data
frame size that the LEC can transmit or receive to 1516 octets.
Using the BCC
To change the maximum data frame size, navigate to the service record prompt
(for example,
box; atm/11/1; lec-service/newyork
) and enter:
maximum-data-frame-size
<value>
value
is the maximum data frame size that you want the LEC to transmit, either
unspecified or 1516.
For example, the following command changes the maximum data frame size to
1516 octets:
lec-service/newyork#
maximum-data-frame-size 1516
lec-service/newyork#