
Site Manager Parameters
117374-C Rev 00
A-49
Parameter: T316
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 120
Options: 1 to 720
Function: Specifies the Restart Request Sent on Interface timer value (in seconds). This
timer begins when the circuit sends a RESTART message to the network. The
circuit uses the RESTART message to return all VCs on the interface to the idle
condition.
The Restart Request Sent on Interface timer stops when the circuit receives a
RESTART ACKNOWLEDGE message from the network.
If the timer expires before the circuit receives a RESTART ACKNOWLEDGE
message, the circuit can transmit as many RESTART messages as specified with
the Num Restarts ReXmitted parameter (see the parameter description on A-53
).
If the circuit still does not receive a response, the circuit enters the null state
until the appropriate maintenance action is taken.
Instructions: Accept the default, 120, or enter a value from 1 to 720.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.30
Comentarios a estos manuales