Avaya Configuring ATM and MPLS Services Manual de usuario Pagina 412

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 529
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 411
Configuring ATM and MPLS Services
A-46
117374-C Rev 00
Parameter: T308
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 30
Options: 1 to 180
Function: Specifies the Release Sent timer value (in seconds). This timer begins when the
circuit sends a RELEASE message to initiate clearing of an SVC. Sending a
RELEASE message places the network in the Release Request state.
The Release Sent timer stops when the circuit receives either a RELEASE
message (that is, both the circuit and the network sent RELEASE messages at
the same time) or a RELEASE COMPLETE message from the network.
If the timer expires before the circuit receives one of these messages, the circuit
transmits the RELEASE message again. If the circuit still does not receive a
response, the circuit releases the call reference and begins a restart procedure.
Instructions: Accept the default, 30, or enter a value from 1 to 180.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.26
Vista de pagina 411
1 2 ... 407 408 409 410 411 412 413 414 415 416 417 ... 528 529

Comentarios a estos manuales

Sin comentarios