Customizing Signaling
117374-C Rev 00
5-3
Disabling and Reenabling Signaling
By default, signaling is enabled on an interface when you create the signaling
object (BCC) or when you create the circuit (Site Manager). However, you can
disable and reenable signaling on an interface at any time.
Using the BCC
To disable signaling, navigate to the signaling prompt (for example,
box; atm/11/1; signaling/11/1
) and enter:
state disabled
For example, the following command disables signaling on the ATM connector:
signaling/11/1#
state disabled
signaling/11/1#
To reenable signaling, navigate to the signaling prompt and enter:
state enabled
For example, the following command reenables signaling on the ATM connector:
signaling/11/1# state enabled
signaling/11/1#
Note:
Disabling ATM signaling on an interface automatically sets the data
encapsulation type to LLC/SNAP and the virtual connection type to PVC for
any new service records.