Customizing Backup Circuits
117353-B Rev. 00
11-17
Enabling Filters for Backup Circuits (frame relay only)
Using Site Manager, you can enable the use of filters across the backup circuits to
prevent unwanted data from keeping the backup circuit active.
To enable filters for the backup circuit, complete the following tasks:
Specifying the Redial Count
Using the BCC, you can specify the number of times the router redials the phone
number to activate the backup circuit.
To configure the number of redials, navigate to the backup-circuit prompt and
enter:
redial-count
<
integer
>
integer can be a value from 1 to 10
For example:
backup-circuit/10/5/1# redial-count 5
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Backup Circuits
. The Backup Circuits menu opens.
3. Choose
Frame Relay.
The FR Primary Interface Definition
window opens.
4. Set the
Use Backup Interface Filters
parameter. Click on
Help
or see the
parameter description on page A-73.
5. Click on
Done
. You return to the Configuration Manager
window.