Dial Service Parameters
117353-B Rev. 00
A-81
Parameter: PPP Circuit Mode
Path: Dialup > Bandwidth On Demand Circuits > Bandwidth On Demand Circuit
Definition > Options > Bandwidth On Demand Monitor Options
Default: Multilink
Options: Multilink
|
Multilink Monitor
|
Dynamic Monitor
Function: Specifies the type of multilink connection for this interface and the value of the
PPP interface parameter PPP Mode.
Instructions: Select one of the following:
Multilink -- Site Manager supplies this value if the Bandwidth Mode parameter
is Non-Monitor. It enables PPP multilink for this circuit. Selecting this value
also prevents you from configuring the other monitor parameters.
Multilink Monitor -- Site Manager supplies this value if the Bandwidth Mode
is Monitor. It enables PPP multilink and tells the router to monitor congestion.
If you configure bandwidth-on-demand service to aid a demand circuit, and this
parameter is set to Monitor, ensure that the demand circuit’s Connection Mode
parameter is set to Collision Master or Collision Slave.
Dynamic Monitor -- Select this option for BAP connections to allocate
bandwidth. This option lets the router function as the monitor or non-monitor
router based on the direction of the call. The router who initiates the call is the
monitor, and the router who receives the call is the non-monitor. If your router is
communicating with a non-Bay Networks router, select this option. If your
router is communicating with a Bay Networks router that uses software prior to
Version 11.01, do not select this option.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.2.2.1.50