Customizing Demand Circuits
117353-B Rev. 00
10-3
Modifying the Frame Relay Interface
Once you configure a frame relay demand circuit, Site Manager configures the
frame relay interface, which you can modify. The interface parameters define the
frame relay characteristics of the circuit, not the demand circuit.
To modify the frame relay interface:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Demand Circuits
. The Demand Pools window opens.
3. Click on
FR Circuits
. The FR Demand Circuits window opens.
4. Click on
Demand Intf
. The FR Demand Interface List window
opens.
5. Set the following parameters:
• FR Service Control
• Mgmnt Type
• Address Type
• Address Length
• Polling Interval
• Full Enquiry Interval
• Error Threshold
• Monitored Events
• Multicast
• Congestion Control
• Congestion Timer
• Congestion Counter
•
Hangup on DLCMI Failure
For information about these
parameters, see
Configuring Frame
Relay Services
.
6. Click on
Apply
, and then click on
Done
. You return to the FR Demand Circuits
window.
7. Click on
Done
. You return to the Demand Pools window.
8. Click on
Done
. You return to the Configuration Manager
window.