Site Manager Parameters
117356-A Rev. A A-81
Parameter: Retransmit Interval
Path: Configuration Manager > Protocols > IP > OSPF > Virtual Interfaces
Default: 5 seconds
Options: 1 to 360 seconds
Function: Indicates the number of seconds between link-state advertisement
retransmissions for adjacencies belonging to this interface. This value is also
used when retransmitting database description and link-state request packets.
This value should be well over the expected round-trip time. Although the
default value is 5, Bay Networks suggests the following values for this
parameter: for broadcast, 10 seconds; for point-to-point, 15 seconds; for
NBMA, 15 seconds; for point-to-multipoint, 15 seconds.
Instructions: Either accept the default value of 5 seconds or set the retransmit interval to
some other value from 1 to 360 seconds.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.2.3.7.1.7
Parameter: Hello Interval
Path: Configuration Manager > Protocols > IP > OSPF > Virtual Interfaces
Default: 15 seconds
Options: 1 to 360 seconds
Function: Indicates the number of seconds between the hello packets that the router sends
on the interface. Although the default value is 15 seconds, Bay Networks
suggests the following values for this parameter: for broadcast, 10 seconds; for
point-to-point, 15 seconds; for NBMA, 20 seconds, for point-to-multipoint, 15
seconds.
Instructions: Either accept the default value of 15 seconds or set the Hello Interval
parameter to some other value from 1 to 360 seconds. This value must be the
same for the virtual neighbor and for all routers attached to the same network.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.2.3.7.1.8