Customizing PVCs
308624-14.10 Rev 01
4-11
Using Site Manager
To enable multicast service, you must set the Multicast parameter for both the
interface and the PVC.
To enable multicast for the interface, complete the following tasks:
Then, enable multicast for the PVC by completing the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Interfaces
. The Frame Relay Interface List window
opens.
4. Set the
Multicast
parameter to
Enable
.
Click on
Help
or see the parameter
description on page A-9.
5. Click on
Apply
.
6. Click on
Done
. You return to the Frame Relay Circuit
Definition window.
7. Click on
Done
. You return to the Configuration Manager
window.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Services
. The Frame Relay Service List window
opens.
4. Click on
PVCs
. The FR PVC List for Service window
opens.
(continued)