Parameter: T308, Release Timer
Path: Configuration Manager > Protocols > Frame Relay > Interfaces > Signaling
Default: 4
Options: 2 to 90 seconds
Function: Indicates the number of seconds allowed for call clearing initiated by the other
end of the connection or when the T305 Disconnect Timer expires:
If timer T305 expires, the router enters the release request state, starts timer
T308, and sends a release message.
Timer T308 stops when the router receives a release complete message from
the other end of the connection.
In the event of a timeout, the router retransmits the release message and restarts
the timer. If the timer expires a second time, the call is cleared. The timer is not
restarted.
Instructions: Enter the timer value for call clearing by the other end of the connection, or
when timer T305 expires.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.9.1.8
Parameter: T310, Call Proceding Timer
Path: Configuration Manager > Protocols > Frame Relay > Interfaces > Signaling
Default: 10
Options: 2 to 90 seconds
Function: Indicates the number of seconds allowed from the time the router receives a call
proceeding message to the time the router receives a connect or disconnect
message.
In the event of a timeout, the router clears the call. The timer is not restarted.
Instructions: Enter the timer value for call proceeding.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.9.1.9