Configuring Frame Relay Services
4-26
308624-14.10 Rev 01
Disabling and Reenabling Data Compression for PVCs
Compression control is enabled by default. You can use either the BCC or Site
Manager to disable or reenable compression for PVCs.
Using the BCC
The
wcp-control
command specifies whether compression is enabled or disabled
for a PVC. By default, compression is enabled.
To disable compression for a PVC, navigate to the prompt for the PVC you want
to modify (for example,
box; serial/1/2; frame-relay/1/2; boston; pvc/1/2/51
)
and enter:
wcp-control
disabled
For example, the following command line disables compression for PVC 51:
pvc/1/2/51#
wcp-control disabled
pvc/1/2/51#
To reenable compression, set this parameter to
enable
.
Using Site Manager
To use data compression with frame relay, first select WCP from the Protocols
menu. Compression is enabled by default for individual PVCs, so you do not have
to set the WCP Enable parameter to use compression.
To disable or reenable data compression, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Services
. The Frame Relay Service List window
opens.
4. Click on
PVCs
. The FR PVC List for Service window
opens.
(continued)