Configuring Congestion Control for an Interface
You can use either the BCC or Site Manager to control congestion for a frame
relay interface.
Using the BCC
To configure congestion control for the interface you must first enable congestion
control. Then, you can optionally configure the congestion timer, congestion
counter, and congestion method.
Congestion Control
Congestion control is disabled by default. To enable congestion control, navigate
to the frame-relay prompt (for example,
box; serial/1/2; frame-relay/1/2
) and
enter:
congestion-control enabled
The value can be
enabled
or
disabled
.
Enabling this parameter tells the router to drop all outbound traffic destined for a
congested SVC until the congestion clears. The value of this parameter affects all
SVCs that you do not individually configure.
For example, the following command line enables congestion control for this
frame relay interface:
frame-relay/1/2#
congestion-control enabled
frame-relay/1/2#
Congestion Timer
To change the value for the congestion timer, navigate to the frame-relay prompt
(for example,
box; serial/1/2; frame-relay/1/2
) and enter:
congestion-timer
<integer>
integer
is the length of time, in seconds, during which the router counts congestion
notifications. If the router receives the number of congestion notifications you set
in the congestion counter during this amount of time, the router stops transmitting
data.
The value can be 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, or 5 seconds. The default is 1.