Customizing SVCs
308624-14.10 Rev 01
5-31
Congestion Counter
To change the value for the congestion counter, navigate to the prompt for the
SVC you want to modify (for example,
box; serial/3/2; frame-relay/3/2; service/
8.0.32; svc-options/toronto
) and enter:
congestion-counter
<integer>
integer
is the maximum number of congestion notifications the router can receive
during the congestion timer period before it stops transmitting data.
The value can be from 1 to 500 notifications. The default is 20.
For example, the following command line sets a congestion counter
of 30 notifications:
svc-options/toronto#
congestion-counter 30
svc-options/toronto#
Congestion Method
To change the value for the congestion method, navigate to the prompt for the
SVC you want to modify (for example,
box; serial/3/2; frame-relay/3/2; service/
8.0.32; svc-options/toronto
) and enter:
congestion-method
<value>
value
can be:
throttle-then-shutdown
-- first queues traffic when congestion occurs, and then
terminates the VC if throttling does not alleviate congestion. This option is valid
only when traffic shaping is enabled.
shutdown
--
the default, terminates the VC when congestion occurs.
throttle
--
queues traffic when congestion occurs; traffic resumes when congestion
clears. This option is valid only when traffic shaping is enabled.
inherit
--
uses the value set for the interface.
For example, the following command line sets a congestion method
of throttle:
svc-options/toronto#
congestion-method throttle
svc-options/toronto#