50
215148-D
Explanation
A switch soft reset has occurred when the global reset counter value
is <number>. The stack manager issue this soft reset the ring
discovery algorithm was not successful after 2 attempts.
Diagnostic Info
Check to make sure that there is no bad cable or unit. Make sure that
you are not resetting or disconnecting units while the ring discovery
algorithm is being executed.
Table 27
Log Entry
Switch Reset, UNP Error, Global Reset Count
Explanation
A switch soft reset has occurred at the specified global reset count.
The stack manager issued the reset because the non-base unit has
not received the upstream next neighbor packet after 2 UNP timer
timeouts.
Diagnostic Info
The unit is not receiving any UNP packet. It may be that the units are
being reset one after another during the boot up phase over an
interval of more than one minute. If this is not the case, make sure
that there is no bad cable or unit.
Table 28
Log Entry
Switch Reset, DbToken Not Received, Global Reset Count <value>
Explanation
A switch soft reset has occurred at the specified global reset count.
The stack manager issued the soft reset because the unit did not
receive the database token after 3 timer timeouts.
Diagnostic Info
This should not happen unless the user repeatedly reset units in the
stack without giving it a chance to join over a period of time.
Table 29
Log Entry
Switch Reset, Db Xchg (got <hexadecimal value>, wanted =
<hexadecimal value) Global Reset Count <value>
Explanation
A switch soft reset has occurred at the global Reset Count. The stack
manager issued the soft reset because database exchanges did not
succeed for all applications. The missing bits in the got <
hexadecimal value> from the wanted <hexadecimal value> indicates
which applications were not successfully.
Diagnostic Info
N/A
Table 26