16
215148-D
a Add the new unit to the stack leaving the original base unit unchanged.
Do not change the base unit switches on the back.
b Power up the stack so that the new unit can learn the IP configuration
and stack information. Verify the configuration of the stack.
c Turn off power to all units in the stack by unplugging the power cords
from each unit.
d Change the base unit selector switch on the new unit so that it is now
base unit.
e Change the base unit selector switch on the original base unit so that it is
not longer configured as the base unit.
8 Power-up the newly joined units by plugging in the power cords and verify the
configuration. It may take a few minutes for the entire stack to display on the
console. All units will display as their new numbers within the newly formed
stack.
If you are running a pure stack that consists of only BPS2000s, and you add a
BayStack 460, a BayStack 470-24T switch, or a BayStack 470- 8T switch to
create an allied stack, you must manually change the base unit from a BPS
2000 switch. (Q00725300)
• The CLI command "default duplex" may not be executed against a
GBIC port. If you execute this command against a GBIC port, you may see
the following error:
% Cannot modify settings
% inconsistentValue <port_number>
(Q00779732)
• When using LAG, a maximum of one standby link is supported. (Q00783242)
• The ports on the BPS2000 2GT MDA may not be the target of the interface
"flowcontrol" command. Changing the flow control of the ports on the
BPS2000 2GT will result in autonegotiation being disabled on the port which
is an unsupported configuration. (Q00787182)
• LAG / IGMP stream does not failover immediately when standby is present.
(Q00804064)
• You must enable IGMP proxy when using IGMP in conjunction with LAG or
MLT. (Q00805627)
Comentarios a estos manuales