Table 16
Log Entry
Incompatible interop value, module <physical id> failed to join stack
Explanation
module <physical id> type cannot interoperate with the base unit’s
interop value.
Diagnostic Info
Replace module <physical id> with another module type that is
compatible with the base’s interop value.
Table 17
Log Entry
Incompatible operational mode, module inactive, module <physical
id> failed to join stack
Explanation
module <physical id> has transitioned to inactive state. When there is
a configuration change, the base unit will re-transmit the “UNP”
packet and a unit upon receiving it may find that it is no longer active
or in the stack.
Diagnostic Info
Find out why module <physical id> became inactive.
Table 18
Log Entry
IN stack port wrapped; check for bad cable or unit.
Explanation
The unit did not receive any acknowledgment when it communicates
with its upstream unit.
Diagnostic Info
First, determine whether you have a bad cable or a bad upstream
unit. If the cable connected to IN stack port is bad, the stack port on
both ends of the cable should be wrapped out and the units attached
to the cable should still be in stack. Also, the unit that is attached to
the other end of the cable should have the entry "OUT stack port
wrapped; check for bad cable or unit". Replace the cable with a good
one, and reboot the units that were attached to this cable.
On the other hand, if the upstream unit is bad, the downstream led on
the upstream unit should be amber and the upstream unit will not be
in stack. Replace the upstream unit.
Table 19
Log Entry
OUT stack port wrapped; check for bad cable or unit.