Avaya BayStack Operating System Switching Software (BoSS 3.1) for BayStack 460, 470 aviso Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 86
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
17
Release Notes for BayStack Operating System Switching Software (BoSS) 3.1
If you initiate a management session with the device through the console port,
you may see the following message in your system log.
session opened from 127.0.0.1
127.0.0.1 is the loopback address and this message is appropriate since the
connection was physically initiated from the console port on the device.
(Q00826743)
The CLI command "show running-config" will display the
configuration parameters that are appropriate for the user that is logged into
the device. A subset of the configuration parameters is displayed to the
READ-ONLY (RO), while a more verbose set of parameters is available to the
READ-WRITE (RW) user. (Q00827993)
Changes to the "cmd-interface" command will take effect when the user
next logs into the device. (Q00829147)
When using TFTP Transfers and a file not found error occurs you may see the
following error message on the console screen:
Error code 1: File not found
You may ignore this error message. (Q00726506)
Managing a LAG from a BayStack 450 in a mixed stack is not supported.
(Q00750550)
BPS/460-Changing from 10MB to 100 MB may result in port remaining in a
down condition (Q00630821)
MLT / LAG console menu screen may display more port members when
moving cables. Refresh the screen should this occur. (Q00770784)
You may not configure the rate-limiting feature for a standalone unit through
the CLI. Please configure this feature through the Web or the Menu Interface
(Q00853102).
When configured in a BayStack 450, the speed and duplex setting on the
BPS2000-4TX MDA, port 25 may change after soft reset (Q00585849)
No trap is sent after a BPS2000 unit which goes down and then comes back up
(Q00691410)
You cannot use Device Manager to download a binary configuration file. Use
the console, Web-based management, or Command Line interface.
(Q00689710)
On the BayStack 450 in a mixed stack configuration, make sure that you
re-enable Global Security when you make any changes to the security
parameters to ensure that the changes take effect. (Q00620973)