Configuring BOOTP Services
2-13
3. Specify the input IP and output IP addresses.
Use the descriptions that follow as a guide.
4. Click on OK.
The BOOTP Relay Agent Forwarding Table window now lists the interface
pair you added and default values for the Enable/Disable and Pass Through
Mode parameters. Note that if you entered an IP address that you have not
configured on the router,
??? appears before the IP address (example:
??? 111.111.111.111). When you configure the IP address on the router, Site
Manager replaces
??? with the appropriate address.
5. Edit the Enable/Disable and Pass Through Mode parameters, if you
want.
Use the descriptions that follow as a guide.
6. Click on Done to exit the window.
Parameter: Input IP Address
Default: None
Options: Any valid IP address
Function: Specifies the IP interface that receives BOOTREQUEST packets from
clients.
Instructions: Enter the IP address of a numbered network interface that you want to
receive BOOTREQUEST or DHCP packets from clients, then configure
this IP address on the router, if you have not already done so.
Do not specify an unnumbered interface for this parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.8.3.2.1.3
Comentarios a estos manuales