Configuring SNMP, BOOTP, DHCP, and RARP Services
2-10
2.
Click on the interface for which you want to edit BOOTP parameters.
3. Edit the parameters you want to change.
Use the descriptions that follow as a guide.
4. Click on Apply to implement your changes.
You can also perform the following procedures from this window:
5. Click on Done to exit the window.
Parameter: Enable/Disable
Default: Enable
Options: Enable
| Disable
Function: Specifies whether BOOTP is active on the network interface.
Instructions: Select Enable to enable BOOTP on the network interface.
Select Disable to disable BOOTP on the network interface.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.8.3.1.1.2
Parameter: Hops
Default: 4
Range: 1 to 16 hops
Function: Specifies the maximum number of hops from the client to the server. A
hop is the logical distance between two devices. If the value in the hops
field of a BOOTREQUEST packet is greater than the number you specify
for this parameter, the router drops the packet.
Instructions: Accept the default of 4 hops or specify a number between 1 and 16,
inclusive.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.8.3.1.1.5