Using the Bay Command Console (AN/BN Routers)
3-10 117383-A Rev. A
If you press Return before entering a sufficient number of characters for the BCC
to recognize the name of the object or parameter you want to configure, the BCC
returns an error message:
box# invalid command name “
<string>
Specifying Parameter Values
You must specify each parameter value in the form of a parameter-value pair.
Each pair is a command argument pertaining to the object named first in the
command line.
For example, the following command changes the BOFL timeout interval from 5
seconds to 4 seconds on ethernet/1/1:
box# ethernet/1/1 bofl-timeout 4
ethernet is the object type, and 1/1 represents the specific slot and connector
location for this Ethernet port.
bofl-timeout is the Ethernet interface parameter you want to modify, and 4 is the
new value for the
bofl-timeout parameter.
bofl-timeout 4 is the parameter-value pair.
Required, Derived, and Other Parameters
The BCC indicates when parameter values are required (you must supply a value)
or derived (the BCC supplies a value). For all other parameters, the BCC supplies
a user-modifiable default value.
Note: The BCC uses required parameters to make up the unique instance
identifier for a configured object. You cannot change the value of any
parameter that makes up the instance identifier for an object. To change these
parameter values, you must delete the object, and then add it back into the
device configuration with new values.