Avaya Configuring Ethernet, FDDI, and Token Ring Services Manual de usuario Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 136
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
Configuring Ethernet, FDDI, and Token Ring Services
3-24
305259-A Rev 00
Specifying the LER Alarm Rate
The LER alarm rate is an estimate at which a link connection generates an alarm.
The LER alarm ranges from 10
-4
to 10
-15
and is reported as the absolute value of
the base 10 logarithm of the estimate. By default, the LER alarm is 10
-8
.
To set the LER alarm rate, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose a
FDDI
Connector.
The Edit Connector window opens.
2. Choose
Edit Line
. The Edit FDDI Parameters window
opens.
3. Choose
Expert
. The FDDI Advanced Attributes window
opens.
4. Choose
Port Attributes
. The FDDI Port Attributes window opens.
5. Set the
LER Alarm
parameter. Click on
Help
or see the parameter description on
page A-12
.
6. Click on
OK
. You return to the FDDI Advanced
Attributes window.
7. Click on
Done
. You return to the Edit Connector window.
8. Click on
Done
. You return to the Configuration Manager
window.
Vista de pagina 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 135 136

Comentarios a estos manuales

Sin comentarios