Configuring Ethernet, FDDI, and Token Ring Services
3-20
305259-A Rev 00
Specifying the Minimum TVX
The minimum TVX must be:
• Greater than 0
• Less than the requested TTRT value
By default, the minimum TVX is 2.5 ms. See Figure 3-2
on page 3-19 for the
range of values for TVX lower bound, in relation to the other TTRT parameters.
To set the minimum TVX, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose a
FDDI
Connector.
The Edit Connector window opens.
2. Choose
Edit Line
. The Edit FDDI Parameters window
opens.
3. Choose
Expert
. The FDDI Advanced Attributes window
opens.
4. Choose
Path Attributes
. The FDDI Path Attributes window opens.
5. Set the
Tvx Lower Bound (ms)
parameter. Click on
Help
or see the
parameter description on page A-11
.
6. Click on
OK
. You return to the FDDI Advanced
Attributes window.
7. Click on
Done
. You return to the Edit Connector window.
8. Click on
Done
. You return to the Configuration Manager
window.
Comentarios a estos manuales