Vista de pagina 106
BCC show Commands
305259-A Rev 00
B-7
Internal MAC Errors Number of excessive deferrals. An excessive deferral indicates that
during the previous transmission the deferral time was greater than
2.46 ms and the transmission was aborted.
Deadlock Errors Number of times the hardware entered a transmitter lockup
condition and the software attempted to work around the condition.
Excessive Collisions Number of times the transmitter failed in 16 attempts to successfully
transmit a message due to repeated collisions on the interface.
Late Collisions Number of collisions that occurred after the timeslot of the channel
elapsed.
System Errors
Slot/Conn Slot location of the Ethernet module within the chassis and the
connector number.
Memory Errors Number of internal memory errors. If this error persists, replace the
Ethernet interface hardware.
Collision Errors Number of times the driver detects that the external transceiver has
not performed the SQE test after frame transmissions. When the
SQE test is enabled on the transceiver, the transceiver asserts
collision to the Ethernet interface after every transmission to provide
an ongoing confidence test of the collision detection circuitry. An
increase in this statistic may mean only that you need to enable the
SQE test on the transceiver.
Internal Errors Number of internal buffer errors. If this error persists, replace the
Ethernet interface hardware.
Loss of Carrier Number of loss of carrier errors, in which the transceiver fails to
sense the carrier signal on the interface.