Configuring Ethernet Services
305259-A Rev 00
2-7
The BofL timeout interval is 5 seconds by default. You can change the interval of
BofL messages to a value from 1 to 60 seconds.
Using the BCC
To change the interval of BofL messages on an Ethernet interface, access an
existing Ethernet line service and enter:
bofl-timeout
<integer>
integer
is the timeout value expressed in seconds. You can enter any integer value
from 1 to 60.
For example, to set the timeout value to 10 seconds, enter the following command
sequence:
box#
ethernet slot 13 connector 1
ethernet/13/1#
bofl-timeout 10
Using Site Manager
To change the interval of BofL messages, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose an
XCVR
Connector.
The Edit Connector window opens.
2. Choose
Edit Line
. The Edit CSMA/CD Parameters window
opens.
3. Set the
BofL Timeout
parameter. Click on
Help
or see the parameter description on
page A-3
.
4. Click on
OK
. You return to the Edit Connector window.
5. Click on
Done
. You return to the Configuration Manager
window.
Note:
In Site Manager, the BofL Timeout parameter is valid only if you set the
BofL Enable parameter to Enable.
Comentarios a estos manuales