Vista de pagina 20
Getting Started
305259-A Rev 00
1-3
back
back
tokenring slot 9 connector 1
circuit-name O91
speed 4Meg
ip address 192.168.2.1 mask 255.255.255.0
arp
back
rip
back
back
back
To access line services, at the top-level box prompt use the output from the
show
config -all
command and enter:
<interface_type>
slot
<
slot_number>
connector
<
connector_number
>
For example, to access the Ethernet line services on slot 13, connector 1, navigate
to the top-level box prompt and enter the following command:
box#
ethernet slot 13 connector 1
To display the current values for the Ethernet line services, enter the following
command:
ethernet/13/1#
info
on box
state enabled
circuit-name E131
slot 13
connector 1
bofl enable
bofl-timeout 5
hardware-filter disable
transmit-queue-length 0
receive-queue-length 0
bofl-retries 5
bofl-tmo-divisor 1
bofl-number 0
interface_type
Name of a physical interface on the router
slot_number
Number of the slot on which the link module is located
connector_number
Number of a connector on the link module