Avaya Configuring Ethernet, FDDI, and Token Ring Services Manual de usuario Pagina 123

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 136
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 122
BCC show Commands
305259-A Rev 00
B-23
show token-ring alerts
The
show token-ring alerts
command displays all token ring modules that are enabled
but not up. Use this display to identify interfaces that are not working.
This command allows for the following command filters (flags) and filter arguments:
The output includes the following information:
Errors Total number of receive, transmit, and system errors (see
show
fddi errors
for greater detail).
This value also includes:
Port operation error events
SMT receive ring error events
LLC/SMT transmit ring error events
Host error events
MTU MTU size for frames on this line.
-circuit
<circuit_name>
Displays information about the specified circuit only.
-slot
<slot>
Displays information about the specified slot only.
<circuit_name>
Displays information about the specified circuit only.
Slot/Conn Slot location of the token ring module within the chassis and the
connector number.
Circuit Name of the circuit associated with this line.
Admin State Configured state of the token ring interface: Up or Down.
HW Address Line’s physical address. The driver assigns this address.
Operational State State of the line: Up, Down, Init (initializing), or Not Pres (enabled
but not yet started).
The Not Pres state occurs for several reasons. For example, the link
module may not be physically present in the chassis; the software
may be booting and has not yet initialized the driver software; the
slot may be running diagnostics; or there may be a problem with the
configuration.
(continued)
Vista de pagina 122
1 2 ... 118 119 120 121 122 123 124 125 126 127 128 ... 135 136

Comentarios a estos manuales

Sin comentarios