Error Codes 10-51
Troubleshooting
Chapter 10
7014 Call not completed. The device
could not be connected to.
Verify that the hunt group extension
for Netcon channels is correct.
7015 Unknown exception (caught by
default)
Retry the operation. Contact Avaya.
7101 Serial port does not exist. Check the serial port (COM Port)
selection under Options|Configure|
Switch Connection.
7102 Serial port in use Find out what else could be using
the Serial port. If nothing is, try
restarting the Connection Server.
Refer to “Troubleshooting” in this
chapter.
7103 Serial port failure Make sure the data module or
wallboard is securely plugged in.
Refer to “Troubleshooting” in this
chapter.
7104 Serial port lost carrier. Make sure the data module
connection to the DEFINITY
system is intact. Refer to
“Troubleshooting the Data Module”
in this chapter.
7105 Receive buffer overrun BCMS Vu recovers from this
problem automatically. If it occurs
frequently, try adjusting the buffer
speed through
Start/Settings/Control
Panel/System/Device
Manager/Com Port/Port
Settings/Advanced. See “Resolving
Problems” on page 10-2.
7106 Serial receive error Check that the serial port connection
is securely attached. Retry the
connection.
ID Description Resolution