Resolving Problems 10-5
Troubleshooting
Chapter 10
Attempted to start Server
or Wallboard software.
Received message that
Omninames and/or
ConnectionServer is/are
not running.
Omninames and/or
ConnectionServer is/are not
running.
1. Close all applications.
2. Reboot the PC.
3. Wait three minutes.
4. Restart Server software.
This allows time for the
TCP/IP stacks to correctly set
up on your PC/LAN.
or
Restart Omninames and
ConnectionServer:
1. Open C:\Programs
Files\Avaya\
BCMS Vu\Common.
2. Double-click on
ConnectionServer.exe.
3. Press Ctrl-Alt-Del to open
the “Windows NT
Security” window
(Windows NT 4.0) or
“Close Program” window
(Windows 95 or 98).
4. Select Task Manager
(Windows NT4.0 only).
5. In the “Windows NT Task
Manager” window or
“Close Program” window,
verify that
ConnectionServer.exe is
running.
Starting/Connecting Problems
Problem Probable Cause Action