Configuring ATM Services
5-10
117374-B Rev. 00
Using the BCC
To change the PCR value for a PVC, navigate to the PVC prompt (for example,
box; atm/11/1; pvc-service/boston; pvc/11/1/0/32) and enter:
pcr
integer
integer is the PCR value that you want the PVC to use.
For example, the following command changes the PVC PCR value to 8000:
pvc/11/1/0/32# pcr 8000
pvc/11/1/0/32#
Using Site Manager
To change the PVC PCR value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Service Attributes
. The ATM Service Records List window
opens.
3. Click on the PVC service record that you
want to modify.
4. Click on
PVC
. The ATM Virtual Channel Link window
opens.
5. Click on the PVC that you want to modify.
6. Set the
Xmit Peak Cell Rate (cells/s)
parameter. Click on
Help
or see the
parameter description on page A-20.
7. Click on
Done
. You return to the ATM Service Records
List window.
8. Click on
Done
. You return to the Edit ATM Connector
window.
9. Click on
Done
. You return to the Configuration Manager
window.