Customizing Signaling
117374-B Rev. 00
4-37
To change the ILMI VPI number, complete the following tasks:
Changing VCI Numbers
By default, the VCI for the signaling control VC is 5 and the VCI for the ILMI
control VC is 16. However, you can change the VCI number to any value from 1
to 65535.
Using the BCC
To change the signaling VCI number, navigate to the signaling prompt (for
example,
box; atm/11/1; signaling/11/1
) and enter:
vci
integer
integer is the VCI number that you want the ILMI VCI to use.
For example, the following command changes the ILMI VCI number to 32:
signaling/11/1#
vci 32
signaling/11/1#
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Interim Local Management
Interface (ILMI)
.
The ATM ILMI Signaling Parameters
window opens.
3. Click on
ILMI VC
. The ATM Control VC for ILMI window
opens.
4. Set the
ILMI VPI
parameter. Click on
Help
or see the parameter description on
page A-46.
5. Click on
Done
. You return to the ATM ILMI Signaling
Parameters window.
6. Click on
Done
. You return to the Edit ATM Connector
window.
7. Click on
Done
. You return to the Configuration Manager
window.