Avaya Configuring ATM Services Manual de usuario Pagina 183

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 411
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 182
Customizing Signaling
117374-B Rev. 00
4-63
Using the BCC
To change the maximum connection control value, navigate to the SSCOP prompt
(for example,
box; atm/11/1; signaling/11/1; sscop/11/1) and enter:
connect-control-maximum
integer
integer is the count value that you want the controller to use.
For example, the following command changes the maximum connection control
value to 6:
sscop/11/1# connect-control-maximum 6
sscop/11/1#
Using Site Manager
To change the Maximum connection control value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Signaling AAL (SAAL)
. The ATM Signaling AAL Records List
window opens.
3. Set the
Max Connection Control
parameter. Click on
Help
or see the
parameter description on page A-56.
4. Click on
Done
. You return to the Edit ATM Connector
window.
5. Click on
Done
. You return to the Configuration Manager
window.
Vista de pagina 182
1 2 ... 178 179 180 181 182 183 184 185 186 187 188 ... 410 411

Comentarios a estos manuales

Sin comentarios