Avaya Configuring ATM Services Manual de usuario Pagina 104

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 411
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 103
Configuring ATM Services
3-6
117374-B Rev. 00
For example, the following command sequence reenables the data path notify
function on the ATM interface and sets the data path notify timeout value to 2400
seconds:
atm/11/1# dp-notify enabled
atm/11/1# dp-notify-timeout 2400
atm/11/1#
Using Site Manager
To disable or reenable the data path notify function or change the data path notify
timeout value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Line Attributes
. The ATM/ARE Line Driver Attributes
window opens.
3. Set the
Data Path Enable
parameter.
Click on
Help
or see the parameter
description on page A-5.
4. Set the
Data Path Notify Timeout
parameter. Click on
Help
or see the
parameter description on page A-5.
5. Click on
OK
. You return to the Edit ATM Connector
window.
6. Click on
Done
. You return to the Configuration Manager
window.
Vista de pagina 103