Customizing Signaling
117374-B Rev. 00
4-25
To reenable automatic restart messages, navigate to the signaling prompt and
enter:
send-restart enabled
For example, the following command reenables restart messages on the ATM
connector:
signaling/11/1# send-restart enabled
signaling/11/1#
Pacing Calls
You can define how the circuit paces its calls. By default, this feature is 0 (off); the
circuit transmits call setups at line rate. However, you can set this value from 0 to
2147483647 calls per second.
To change how the circuit paces its calls, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Signaling Attributes
. The ATM Signaling Parameters window
opens.
3. Set the
Num Messages/Sec for Call
Pacing
parameter. Click on
Help
or see
the parameter description on page A-45.
4. Click on
Done
. You return to the Edit ATM Connector
window.
5. Click on
Done
. You return to the Configuration Manager
window.