Chapter 61 Data modules 531
BCM 4.0 Networking Configuration Guide
3 Configure the setting to match the DTE you are connecting to the DDI Mux.
Table 121 describes the Data Module configuration settings.
Table 121 DDI Mux Configuration settings
Setting Value Description
SDI Configuration
Protocol V.35
RS232
RS449
EIA-530
EIA-530A
Interface standard used by the connection between the DDI Mux and
the BCM WAN card or by the connection between the DDI Mux and an
external router.
Default: V.35
B channel data
rate
64 K
56 K
Select the transmission rate per channel (Fixed data lines) assigned to
the module.
Transmit clock
source
Auto
DCE
DTE
The DDI Mux requires a timing signal to clock data transmitted by the
DTE. This signal can be supplied by the DTE or generated internally by
the BCM. If the signal is generated by the DTE, the clock must be
locked to the frequency of the DDI Mux clock.
Auto: The DDI Mux checks if the clock provided by the DTE is
valid. If the clock is valid, the module uses DTE clocking. If the DTE
clocking is not valid, the module uses its own internal clock (DCE).
DCE: The internal TxSync clock is used to clock data.
DTE: The TXClk clock provided by the DTE is used by the DDI Mux
to clock data.
Note: Use the DTE option only for diagnostic purposes.
For all options, the DTE must synchronize to the module.
Transmit clock
inversion
<check box> When the internal DCE signal is used to clock in data, signal delays
caused by cable length can cause clocking errors. To adjust for round
trip delays between the DDI Mux and DTE, invert the internal clock
used by the module to clock in data from the DTE.
To enable clock inversion, select the DTE clock or Auto clock.
Data inversion <check box> When Data Inversion is selected, the DDI Mux inverts the data before
routing it to the T1 connection and DTE. Inversion allows the module to
use the properties of protocols such as HDLC/SDLC (a transmission
standard for data) to meet the ones density requirement of the
network. This feature must be available and activated at the far end.
Loopback status
Loopback state <read-only> Indicates the loopback state.
Loopback Off
Manual DTE
Manual DS30
Automatic DTE
Off: No loopback is active.
Manual DTE: The SDI takes the data received from the DTE and loops
it back towards the DTE.
Manual DS30: The SDI takes the data received from the DS30 bus and
loops it back.
Automatic DTE: The SDI enters in the loopback state when requested
by the DTE. Auto DTE should only be set when supported by DTE.