346 Chapter 33 Private networking: MCDN over PRI and VoIP
N0060606N0060606
Routing is set up such that network calls are made by dialing a four-digit private network DN. For
example, if a user in the West End branch wishes to call a user in the East End branch within the
private network, they dial 6221. Figure 117 illustrates this example.
The implications on the configuration on each node to access the PSTN through one network node:
Each node must have the Private Network Access Code set to the value 9.
Each node must have destination codes that match the Private Network Access Code plus
digits corresponding to calls terminating in the local PSTN. For example, if the Private
Network Access Code is 9, the node in Ottawa would require a destination code of 91613.
Similarly, Toronto would require the following destination code: 91416.
BCM module settings: Table 77 lists the module settings that are required to set up the network
described in Figure 117.
Table 77 Module settings for MCDN network
West End office:
Module programming DTM PRI
Protocol SL-1
BchanSeq Ascend
ClockSrc Primary
East End office:
Module programming DTM PRI
Protocol SL-1
BchanSeq Ascend
ClockSrc Primary