Telephony metrics monitoring 55
Nortel Business Communications Manager 5.0
Fault and Performance Management
NN40170-701 01.01 Standard
August 2009
Copyright © 2009 Nortel Networks
5 Click Reset Statistics to reset new settings.
The system displays a message indicating that this will remove all of the
statistics.
6 Click OK to erase all the current statistics and begin collecting statistics
again.
--End--
Checking the CSU alarms
Check the CSU alarms to view the active loss of signal (LOS), out of frame
(OOF), remote alarm indicator (RAI), or alarm indication signal (AIS) alarms.
Procedure steps
Step Action
1 Select Administration > Telephony Metrics > Trunk Module Metrics.
2 Select a module.
3 Click the CSU Alarms tab.
The display shows all the active alarms of the types LOS (loss of signal),
OOF (out of Frame), RAI (Remote alarm indicator), or AIS (Alarm indication
signal).
--End--
Checking carrier failure alarms
Check carrier failure alarms to view a history of alarms for a module. CFA
types reported by the BCM can be mapped to CFAs defined in TIA-547A and
TR62411 as shown in the table below.
Procedure steps
Step Action
1 Select Administration > Telephony Metrics > Trunk Module Metrics.
2 Select a module.
3 Click the CSU Alarm History tab.
The display shows LOS (loss of signal), OOF (out of Frame), AIS (Alarm
indication signal), and RAI (Remote alarm indicator).