The system accumulates three performance parameters:
errored seconds (ES)
severely errored seconds (SES)
unavailable seconds (UAS)
These parameters are defined according to TIA-547A. Errored seconds are
enhanced to include control slip (CS) events. Only near-end performance data
is recorded.
The internal CSU continuously monitors the received signal and detects four
types of transmission defects:
any active carrier failure alarms (CFA), such as loss of signal (LOS), out
of frame (OOF), alarm indication signal (AIS), and remote alarm indication
(RAI)
the number of bipolar violations that occurred in the last minute
any defects that occurred in the last minute, such as loss of signal (LOS),
out of frame (OOF), and alarm indication signal (AIS)
the number of milliseconds of short-term alarms in the last minute, such
as loss of signal (LOS), out of frame (OOF), alarm indication signal (AIS),
and remote alarm indication (RAI).
A short term alarm is declared when the detected defects persist for tens of
milliseconds. A carrier failure alarm (CFA) is a duration of carrier system
outage.
The criteria for declaring and clearing the alarms is selectable to meet those
in TIA-547A or TR64211. You can also view Carrier Failure Alarms as Core
Telephony Alarms in the Alarm Viewer.
BCM trunk module CSU statistics navigation
Enabling the internal CSU (page 54)
Checking the performance statistics (page 54)
Checking the CSU alarms (page 55)
Checking carrier failure alarms (page 55)
Checking bipolar violations (page 56)
Checking short-term alarms (page 57)
Checking defects (page 57)
Viewing CSU alarm history (page 58)