38 System metrics monitoring
Nortel Business Communications Manager 5.0
Fault and Performance Management
NN40170-701 01.01 Standard
August 2009
Copyright © 2009 Nortel Networks
The UPS Status panel tracks occurrences of alarms pertaining to UPS
operation. These alarms are also sequentially viewable in the Alarm panel.
The metrics correspond to alarms in the BCM and appear in the alarm panel
as well.
Accessing the UPS status
Complete this procedure to verify the status of the UPS before you boot up the
BCM system.
Procedure steps
Step Action
1 Click the Administration tab.
2 In the Navigation tree, click System Metrics >UPS Metrics > Status tab.
The status of the UPS appears. The UPS Status panel confirms that a UPS
is connected including model and serial number, its current status, and
provides a read out of the current values. Additionally, an indication is given
whether the value is within the normal range or not.
3 To check the metrics of the UPS, click the Metrics tab.
The metrics information appears in the panel.
--End--
NTP metrics
Using Network Time Protocol (NTP), you can configure the time on the BCM
indirectly from a single time server. NTP is a network protocol designed to
synchronize the clocks of computers over an IP network. The NTP Metrics
provide an overview of the integrity of the NTP time source. If the BCM clock
control has not been configured to use NTP (Configuration>System>Date &
Time), then the NTP Metrics panel displays no data.