Chapter 6 Command Line Interface (CLI) 79
R2MFC Media Bay Module Installation and Configuration Guide
SubsIndOpt <mfc_link> <flag> Defines which subscriber status to send when an incoming MFC call
terminates successfully.
Where:
mfc_link is the number of the link, 0 or 1.
flag is the subscriber status, 0 (subscriber option is default value) or 1
(subscriber option is received value).
DefltSubsVal
<mfc_link><subscriber>
Defines the subscriber status value when the SubsIndOpt commands is set
to the default value.
Where:
mfc_link is the number of the link, 0 or 1.
subscriber can have the values of:
• 0 = speech_charge (A group)
• 1 = free_charge
• 2 = free_no_charge
• 3 = control_charge
EndDialType
<mfc_link><direction><type>
Defines how to handle MFC end of dial.
Where:
mfc_link is the number of the link, 0 or 1.
direction is 0 (IC), 1 (OG), or 2 (both).
type is either 0 (Ix signal) or 1 (fix number of digits).
SetDigitCount <mfc_link>
<count_type> <value>
Sets the number of expected digits when the EndDialType is set to a fixed
number of digits.
Where:
mfc_link is the number of the link, 0 or 1.
count_type is either 0 (minimal range) or 1 (optional range).
value has values of 3...12 for minimal range or 0...15 for optional range.
EndAniType
<mfc_link><direction><type>
Defines how to determine end of ANI digits.
Where:
mfc_link is the number of the link, 0 or 1.
direction is 0 (IC), 1 (OG), or 2 (both).
type is either 0 (Ix signal) or 1 (fixed number of digits).
SetAniCount <mfc_link> <value> Defines the number of expected ANI digits when EndAniType is set to a
fixed number of digits.
Where:
mfc_link is the number of the link, 0 or 1.
value is the expected number of ANI digits in the range of 1...16.
Table 23 MFC directory CLI commands (Sheet 2 of 3)