Chapter 5 R2MFC MBM maintenance 59
Digital Mobility System Installation and Configuration Guide
Group II errors
Group II alarms occur when an alarm persists for a predefined period. The alarm is considered
cleared when it does not occurred for a predefined period.
See Table 9 for incoming-signal Group II errors listed from highest to lowest priority. Group II
errors are ordered by priority; when a high priority error exists, any errors of lower priority are
irrelevant.
Alarms propagation
This section describes the actions taken when alarms occur or stop. When alarms occur, the
far-end is alerted by a remote alarm indication, and an alarm is transmitted on the opposite link.
Table 10 table shows the reactions for Group I alarms when they enter the Out-Of-Service (OOS)
state.
Table 9 Incoming signal errors
Alarm Cause
Loss of Signal (LOS) No reception of incoming electrical signal on the line (cable cut or
removed).
Alarm Indication Signal (AIS) Reception of incoming signal is all ones. Usually indicates that the
far-end is out-of-service
Out-of-Frame (OOF) No detection of Frame Alignment Signal. The incoming signal is
corrupted. This alarm is also known as Loss of Frame (LFA).
Out Of Multiframe TS16 -
(OOM
TS16
)
No detection of Multiframe Alignment Signal. When this alarm is active,
Channel Associated Signaling (R2) is impossible. This alarm is not
applicable to the PRI (internal link). This alarm is also known as Loss of
Multiframe Alignment - (LMA).
Alarm Indication Signal in TS16
(AIS
TS16
)
Reception of AIS is all ones in TS16. This is an optional alarm. It can be
enabled or disabled in configuration. By default, this option is off. When
this alarm is active, any signaling on TS16 is impossible.
Loss of CRC-4 Multiframe
Alignment (OOM)
CRC-4 multiframe cannot be recognized. When this alarm is active,
CRC-4 errors (of group I) cannot be measured. This alarm is relevant
only when CRC-4 multiframe mode is used.
Remote Alarm Indication (RAI) Indication that the far-end has trouble with its incoming signal. This
alarm is also known as yellow alarm.
Remote Alarm Indication TS16
(RAI
TS16
)
Indication that the far-nd has lost TS16 multiframe alignment on its
incoming signal.
This alarm is not applicable to PRI (internal link).
Table 10 Group I Alarms propagation (Sheet 1 of 2)
Error Condition Alarm Transmitted to far end Alarm sent on opposite link
BPV RAI AIS
FBER RAI AIS
Slips RAI AIS