Validating Avaya 3100 Mobile Communicator Gateway
registration
Use this procedure to determine if the Avaya 3100 Mobile Communicator Gateway is registered
to the Enterprise Communication Server (ECS).
Prerequisites
The Service Number for the trunk between the Avaya 3100 Mobile Communicator Gateway
and the SIP PBX interface is configured on the Avaya Communication Server 2100 (Avaya
CS 2100) ECS, and matches the entered Service Number information in the Avaya 3100
Mobile Communicator Gateway.
1. Log in to the Avaya 3100 Mobile Communicator Gateway through the Admin Login
page.
2. On the System Status tab, check for the presence of alarms under the Last Alarm
Entry column.
3. If an alarm entry exists, click on the link to view the alarm details. If the alarm details
indicate a registration failure, the Avaya 3100 Mobile Communicator Gateway is not
currently registered. Check your configuration and try again.
See the
Job aid on page 130 following this procedure for an example of successful
and unsuccessful registration attempts.
Job aid
The following figure shows a successful registration attempt with no alarms.
Validate deployment
130 Deployment Guide October 2010