Installing and Maintaining BN Platforms
3-22 109352-E Rev. A
2. If you have not already done so, remove the cable connector from the
CONSOLE port of the System Resource Module-Link (SRM-L).
The SRM-L resides in Slot 7 of the BCN rear panel.
3. Insert one end of the modem cable (Order No. 77850) into the
SRM-L CONSOLE port.
4. Insert the other end of the cable into the communications port on the
modem.
To configure the BCN CONSOLE port for modem operation, refer to Configuring
Routers (router software) or Getting Started with Site Manager (BayStream
software).
Table 3-9. Modem Operating Parameters
Parameter Setting
Baud rate 9600 or less
Auto answer Set on
n
rings with DTR active
(
n
must be greater than 0)
Clear to Send (CTS) signal Always ON
Data Terminal Ready (DTR) signal DTR signal fail-disconnect enabled (return
to command mode, auto-answer off)
Data Carrier Detect (DCD) signal DCD signal on while carrier present (the
node uses DCD to detect modem
disconnect)
Local character echo OFF
Supervisory functions OFF
Data Set Ready (DSR) signal ON
Note: The console cable and the modem cable both connect to the BCN using
the CONSOLE port.